1.Walk me through how you'd diagnose a hydraulic function that's slow on one side of a machine only.
Why they ask
Hydraulic faults are where parts-changers get exposed. They want to hear a method, not a guess.
How to answer
- Start with the basics: fluid level, contamination, and whether the operator is describing it accurately
- Isolate the circuit using the schematic, since one side slow points away from the pump
- Put gauges or a flow meter on it and compare readings against the service manual spec
- Check the valve section, relief setting and cylinder or motor for internal leakage before ordering parts
- Mention a real machine where you did this and what the cause turned out to be