1.A customer calls saying their collector's differential pressure is way higher than normal. Walk me through what you'd check.
Why they ask
High pressure drop is the most common service call, and the order you check things tells them whether you troubleshoot or just replace filters.
How to answer
- Confirm the gauge and its pressure lines are good first, since a plugged tap or kinked tube gives a false reading
- Check compressed air supply pressure at the header and whether it's dry
- Listen to the pulse sequence and look for valves that don't fire, then test the diaphragms and solenoid coils
- Check the timer or controller settings and whether cleaning is on demand or continuous
- Only then consider blinded filters, and look for why they blinded, like moisture or a process change